REMOTE SENSOR CONFIGURATION MENU
The configuration menus allow you to set certain remote sensor operating characteristics to your system or personal require-
ments. Two configuration menus are available, User Configuration and Installer Configuration.
User Configuration Menu
Momentarily press
and keys at the same time and release to enter the User menu. To scroll through the menu
items press the
and keys at the same time. To change the item option press or . To exit the menu
scroll through all menu items. If no buttons are pushed for 3 minutes, the control will also return to normal operation.
The User Configuration Menu table summarizes the configuration options. An explanation of each option follows.
Step Press button(s) Displayed Press
or Comments
to scroll menu (factory default) to change option
1
and LOCK on Select keypad lockout OFF or ON
(OF)
2
and HLD 1 to 8 hrs Select temporary adjust thermostat setpoint
(4h) in 1 hour increments hold time
3
and CALIB 1-4 bars (1°-4°) C to Select temperature display adjustment
(Sensed Temperature) 1-4 bars (1°-4°) H higher or lower
4
and d
F
OF Select display temperature OFF or ON
(on)
5
and dL OF Select display backlight OFF or ON
(on)
6
and
o
F
o
C Select temperature display to F or C
(Sensed Temperature)
7
and _____ _____ Exits user menu and returns to normal
operation
User configuration menu
1) Select keypad lockout OFF or ON – Selecting LOCK
ON will cause the keypad to be locked in the normal
operation mode. This prevents the and from
being used to adjust temperature. The display will
indicate "LOCK" when the keypad is locked. If LOCK OF
is selected, the
and keys can still be used.
When the keypad is locked, the and keys can
still be pressed at the same time to enter the configura-
tion menu.
2) Select temporary adjust thermostat setpoint hold time
– Selects the length of time for the temporary thermostat
setpoint adjustment. Hold time default is 4 hours and can
be set from 1 to 8 hours in 1 hour increments.
3) Select temperature display adjustment higher or
lower – allows you to adjust the room temperature
display 1° to 4° higher or lower. Your sensor was accu-
rately calibrated at the factory but you have the option to
change the display temperature to match your previous
sensor or thermostat.
4) Select display temperature OFF or ON – Selecting OF
allows you to disable displaying the sensed temperature.
Instead of the temperature, the sensor will display "PWR"
with the word on to indicate normal operation. With
display OFF the Transmitting icon will not appear.
5) Select display backlight OFF or ON -. The display
backlight improves display contrast in low lighting
conditions. Selecting dL on will keep the light on for a
short period of time after any key is pressed. Selecting
OF will keep the light off.
6) Select temperature display to
o
F or
o
C - Changes the
display readout to Celsius or Fahrenheit as required.