White Rodgers 50A56-956 Manuel d'installation Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
7
OPERATION
To reset the control after system lockout, do one of the
following:
1. Interrupt the call for heat or cool at the thermostat for at least
one second but less than 20 seconds (if flame is sensed
with the gas valve de-energized, interrupting the call for
heat at the thermostat will not reset the control).
2. Interrupt the 24 VAC power at the control for at least one
second. You may also need to reset the flame rollout sensor
switch.
3. After one hour in lockout, the control will automatically reset
itself.
DIAGNOSTIC FEATURES
The 50A56-956 control continuously monitors its own operation
and the operation of the system. If a failure occurs, the LED will
indicate a failure code as shown in the TROUBLESHOOTING.
Ifthefailureisinternaltothecontrol,theLEDwillstayon
solid.Inthiscase,theentirecontrolshouldbereplaced,
asthecontrolisnoteld-repairable.
Failure codes will flash the LED in the following flash-
pause sequences to indicate failure status (each flash will
last approximately 0.25 seconds, and each pause will last
approximately 2 seconds).
FAULT RECALL
The last five fault codes stored can be displayed on the
diagnostic LED. When the control is in standby mode (no
call for heat or cool), press the FAULT RECALL switch for
approximately two to five seconds and release. The fault codes
will display beginning with the most recent fault first with a one
second pause between codes. After the stored fault codes
have all displayed, the LED will return to normal status. While
displaying the stored fault codes, the control will ignore any
new call for heat, cool or fan. If no fault codes are in memory,
the LED will flash two green flashes then return to normal
status.
FAULT CODE RESET
The stored fault codes can be erased from memory. When
the control is in standby mode (no call for heat or cool), press
the FAULT RECALL switch for five to ten seconds or until
the diagnostic LED begins to rapid flash. When the switch is
released, the LED will flash three green flashes when memory
has been cleared.
The 50A56-956 has only one serviceable part –an automotive
type fuse, which protects the low voltage transformer from
damage if the output is short-circuited. If the fuse has opened
up, remove whatever caused the short circuit and replace the
fuse with only a 3 Amp automotive type fuse. If the fuse does
not correct the condition, replace the entire control. There are
no other user serviceable parts.
MANUAL FAN ON MODE
If the thermostat fan switch is moved to the ON position, the
optional electronic air cleaner and circulator fan are energized.
The circulator speed is selectable via shunt jumper option E33.
Three choices that can be made are Lo Cool, Heat or Hi Cool.
By moving the shunt jumper location, the desired continuous
fan speed will be attained. When the fan switch is returned to
the AUTO position, the circulator fan and electronic air cleaner
(optional) are de-energized.
E34
DELAY
OFF
BLWR
180
120
90
60
180
120
90
60
180
120
90
60
180
120
90
60
Heat Delay-to-Fan-Off
Shunt Jumper E34
Manual Fan Speed
Shunt Jumper E33
Factory Setting
120 Seconds
Factory Setting
HI COOL
LO COOL HEAT
60 Seconds
90 Seconds 180 Seconds
E33
SPEED
FAN
CONT
HI COOL
HEAT
LO COOL
HI COOL
HEAT
LO COOL
HI COOL
HEAT
LO COOL
TWINNING INTERFACE
The control is equipped with a single wire twinning interface which
is a 3/16" spade terminal designated as "TWIN". If twinning is
used, either control will process a call for heat, cool or fan as
described above. However, after the heat-, cool-, or fan-on delay
time expires, both units will energize the circulator blowers at
the same time. Likewise, after the heat-, cool-, or fan-off delay
time expires, both units will de-energize the circulator blowers
at the same time. This allows for proper air flow to be obtained.
To assure proper control operation, both controls must share a
common transformer ground (TR).
To enable twinning, do the following.
1. Power supplied to both furnaces must be from the same
phase of the 24 VAC power to the control.
2. Connect the TWIN terminals on the controls of the furnaces
to be twinned to each other using a single wire (14-22
AWG.).
3. Both controls must be of the same model and type for the
twinning feature to work properly.
SYSTEM LOCKOUT
SYSTEM LOCKOUT FEATURES
When system lockout occurs, the gas valve is de-energized,
the circulator blower is energized at heat speed, and, if flame
is sensed, the inducer blower is energized. The diagnostic
indicator light will flash or glow continuously to indicate system
status. (Systemlockoutwillneveroverridetheprecautionary
features.)
Vue de la page 6
1 2 3 4 5 6 7 8 9 10 11 12

Commentaires sur ces manuels

Pas de commentaire